DUCTING REQUIREMENTS
•   Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
•   Do not use a smaller duct.
•   Ducts larger than 4 inches (10.2 cm) in diameter can result in increased lint accumulation. 
 
Lint accumulation should be cleaned regularly.
•   If a fl exible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a fl exible 
 
duct with a thin foil wall. Serious blockage can result if the fl exible metal duct is bent too sharply.
•   Never install any type of fl exible duct in walls, ceilings, or other concealed spaces.
•   Keep exhaust duct as straight and short as possible.
•   Secure joints with duct tape. Do not use screws.
•   DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE, OR CONCEALED SPACE OF A  
 
 
BUILDING, GAS VENT, OR ANY OTHER COMMON DUCT OR CHIMNEY. 
 
THIS COULD CREATE A FIRE HAZARD FROM LINT EXPELLED BY THE DRYER.
•   Plastic fl exible duct can kink, sag, be punctured, reduce airfl ow, extend drying times, and affect dryer  
 
 
 operation.
•   Exhaust systems longer than recommended can extend drying times, affect machine operation, and may collect lint.
•   The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts 
 
and entry of wildlife. Never use an exhaust hood with a magnetic damper.
•  The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and  
 
 
 
the ground or other obstruction. The hood opening should point down. 
•  Never install a screen over the exhaust outlet.
•  To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a  
 
 
 
house or porch.
•  If exhaust ductwork must run through an unheated area, the duct should be insulated and slope   
 
slightly down towards the exhaust hood to reduce condensation and lint buildup.
•   Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord  
 
 
 before 
cleaning.
•   Check frequently to be sure the exhaust hood damper opens and closes freely.
ELECTRIC AND GAS DRYER
Weather Hood Type
Recommended
Use only for short-run installation
No. of 90° 
elbows
Rigid
Metallic Flexible*
Rigid
Metallic Flexible*
0
24.4 m (80 ft.)
12.4 m (41 ft.)
22.6 m (74 ft.)
10.1 m (33 ft.)
1
20.7 m (68 ft.)
11.2 m (37 ft.)
18.9 m(62 ft.)
8.8 m (29 ft.)
2
17.4 m (57 ft.)
10.1 m (33 ft.)
15.5 m(51 ft.)
7.6 m (25 ft.)
3
14.3m (47 ft.)
9.0 m (29 ft.)
12.5 m(41 ft.)
6.5 m (21 ft.)
* Do not use non-metallic fl exible duct.
4” (10 .16 cm
)
2.5” (6.35 cm)