Allied International V2.4.0 Benutzerhandbuch

Seite von 212
Configuration of the camera
OSCAR Technical Manual V2.4.0
193
MinValue and MaxValue limits the range the auto gain feature is allowed to 
use for the regulation process. Both values are initialized with the minimum 
and maximum value defined in the standard GAIN_INQ register.
Changing the auto gain range might not affect the regulation, if the regu-
lation is in a stable condition and no other condition affecting the image 
brightness is changed.
If both auto gain and auto shutter are enabled and if the gain is at its lower 
boundary and shutter regulation is in progress, decreasing the lower auto 
gain boundary has no effect on auto gain/shutter regulation as long as auto 
shutter regulation is active.
Both values can only be changed within the range defined by the standard 
GAIN_INQ register.
Autofunction AOI
The table below illustrates the advanced register for autofunction AOI.
The possible increment of this work area position and size is 128 pixels. The 
camera automatically adjusts the settings to permitted values:
Register
Name
Field
Bit
Description
0xF1000390 AUTOFNC_AOI
Presence_Inq
[0]
Indicates presence of this 
feature (read only)
---
[1..3]
Reserved
ShowWorkArea
[4]
Show work area
---
[5]
Reserved
ON_OFF
[6]
Enable/disable AOI (see note 
above)
---
[7..31]
Reserved
0xF1000394 AF_AREA_POSITION
Left
[0..15]
Work area position
(left coordinate)
Top
[16..31]
Work area position
(top coordinate)
0xF1000398 AF_AREA_SIZE
Width
[0..15]
Width of work area size
Height
[16..31]
Height of work area size
 Table 95: Advanced register: Autofunction AOI
Region
Permitted values
Left, top
0, 128, 256, 384, 512, 768, 1024…
Width, height
128, 256, 384, 512, 768, 1024…
 Table 96: Permitted values for AF_AREA_SIZE