Sony HKCU-902 Benutzerhandbuch

Seite von 74
3-26 (E)
HDCU-900 MM
3-6. HD Signal Input/Output Adjustment (HKCU-902)
5.
R mix level adjustment
Measuring point : P
R
/R OUTPUT1 connector/
ADA-59
Adjusting point :
1RV302 (L-4)/ADA-59
Specifications :
Portion G and portion H must be
flat (within 5 mV or less).
6.
R signal level adjustment
Measuring point : P
R
/B OUTPUT1 connector/ADA-
59
Adjusting point :
1RV303 (M-4)/ADA-59
Specifications :
J = 700 
±5 mV (terminated at 75 Z)
Setting after Adjustment
. S1 (F-2)/ADA-59 → 0
. BARS button/MSU → OFF
3-6-3. SYNC Output Level Adjustment
Measure : HD waveform monitor
Preparation
. Board extension : ADA-59 board (rear side)
. BARS button/MSU → ON
Adjustment Procedure
Measuring point : Y/G OUTPUT1 connector/ADA-59
Adjusting point :
1RV752 (F-4)/ADA-59
Specifications :
A = 600 
±5 mV (terminated at 75 Z)
Setting after Adjustment
BARS button/MSU 
→ OFF
ADA-59 board (A side)
A
B
C
D
E
F
G
H
J
K
L
M
1
2
3
4
5
1
1
RV501
1
RV201
RV102
RV101
RV752
RV103
1
1
1
1
1
1
1
1
1
1
RV301
R
V
303
R
V
302
R
V
203
R
V
202
R
V
104
RV502
S1
RV1
1
Suffix:14
_
TP601
Suffix:14
_
J
Portion G
Portion H
A