3.8.33 MAGNETIC HEADING VALIDITY DISCRETE 
A Magnetic Heading validity discrete may be used by EGPWS for the Magnetic Heading sensor. 
Type:  
Validity from Magnetic Heading sensor.  
Signal Status:   Valid or Invalid  
 
Level 6 Audio readout 
Magnetic Heading Validity Discrete 
Valid => 
Invalid =>
“Magnetic Heading Valid” 
“Magnetic Heading Invalid” 
3.8.34 AOA VANE HEATER DISCRETE 
An AOA Vane Heater Discrete may be used by EGPWS for indication of vane heat for flight history recording. 
Type:  
Heater Flag from AOA vane.  
Signal Status:   Vane Heater On or Vane Heater off  
 
Level 6 Audio readout 
AOA Vane Heater Discrete 
True => 
False =>
“AOA Vane Heater On” 
“AOA Vane Heater Off” 
 
3.8.35 PLI DESELECT SWITCH DISCRETES (MK V AND MK VII ONLY) 
PLI deselect switch discretes may be used by EGPWS for de-activating the PLI select relays to remove EGPWS PLI 
indication from the ADI. 
Type:  
momentary make/break switch  
Signal Status:   EGPWS PLI deselected  
 
Level 6 Audio readout 
PLI Deselect Switch #1 
Pressed  => 
Not Pressed =>
“PLI Deselect Switch 1 True” 
“PLI Deselect Switch 1 False” 
PLI Deselect Switch #2 
Pressed  => 
Not Pressed =>
“PLI Deselect Switch 2 True” 
“PLI Deselect Switch 2 False” 
 
3.8.36 AUTOPILOT DISCONNECT DISCRETES 
Autopilot Disconnect discretes may be used by EGPWS for indication that the Autopilot has been disconnected. 
Type:  
Autopilot Disconnected  
Signal Status:   Autopilot Connected or Not Connected 
 
Level 6 Audio readout 
Autopilot Disconnect #1 
Connected  =>
Not Connected =>
“Autopilot 1 Selected” 
“Autopilot 1 Not 
Selected” 
Autopilot Disconnect #2 
Connected  =>
Not Connected =>
“Autopilot 2 Selected” 
“Autopilot 2 Not 
Selected”