Honeywell MK VI Benutzerhandbuch

Seite von 68
EGPWS LINE MAINTENANCE MANUAL 
CAGE CODE: 97896 
SCALE: NONE     SIZE: A 
DWG NO.:  060-4199-180 
REV:   G 
SHEET  61 of 68 
 
12  APPENDIX B: TROUBLESHOOTING DO’S AND DO NOT’S 
 
DO use built-in self test levels to find the exact nature of the fault. 
DO use our free WinVIEWS program to quickly access Self Test Level 1, 2, and 3 info 
DO remember to look at the front panel LEDs 
 
Green Computer OK LED means “don’t remove” 
 
Amber External Fault LED means “don’t remove” 
 
Red Computer means “possibly remove” 
 
DO NOT use cockpit INOP lamps for troubleshooting 
 
INOP indications are merely a pilot’s indication of which EGPWS functions are inactive, they are not positive 
indication of internal EGPWS faults. Experience shows External (non-EGPWS) faults are responsible for 
INOPs illumination 99% of the time. 
DO NOT remove unit if front panel green Computer OK LED is illuminated