United States Stove HOTBLAST 1950 Benutzerhandbuch

Seite von 20
3.3 
PIPE CONNECTOR AND DAMPER 
 
 
Before proceeding to connection, remove all accessories such as
scraper, shovel and poker from  the evacuation pipe of the furnace. 
    A 7” diameter chimney listed for use with wood burning heating appliances is highly recommended for the 
Hotblast 1950. In this case, a reducer from 7” to 6” is required.  If draft exceed –0.06 in. W.C a barometric damper 
should be installed on the smoke pipe.  Never install a manual damper. 
 
                          
 
REDUCER 
DIAMETER 7 "
 
For a proper installation, follow the advices below: 
 
 
1.  All the joints of the evacuation pipe must be secured, using three screws. 
Make sure that each screw goes through the inner walls of both connectors (male and female).  See 
pictures below showing a male-female coupling. 
 
 
PROPER INSTALLATION  
IMPROPER INSTALLATION 
 
 
 
 
 
CAUSE RESTRICTION 
 
 
 
2.  A minimum rise of 1/4 inch per horizontal foot must be respected. 
 
 
6