Hearth & Home Technologies HUDBAY-FS Benutzerhandbuch

Seite von 49
10/08
Page  33
Quadra-Fire  •  Hudson Bay  •  7003-121 Rev. i
See vent graph for recommendations on page 11 before 
you begin your adjustment.
  If your installation falls within 
the range of the gray shaded area of graph, it may be 
necessary to make an adjustment to the vertical damper to 
improve the flame appearance in your appliance.
NOTE: In the Commonwealth of Massachusetts, the word 
damper shall be replaced with the words flue restrictor.
Figure 8.25
    The shutter is located on the underside of the 
appliance, on the right side.  To adjust the shutter, loosen 
the wingnut.. Retighten the wingnut after adjustment.
Moving the shutter bolt to the right closes the shutter. Moving 
the shutter bolt to the left, will open the shutter. Opening the 
shutter causes flames to become shorter and blue. Closing 
the shutter creates taller orange/yellow flames. 
I.  Damper Adjustment 
J.  Shutter Adjustment
Figure 8.24
   
Open the right side panel to access the shutter 
adjustment.  
Loosen screws and make adjustment according to vent 
chart.  
Make adjustment until fl ame size and activity suits 
your personal preference, and then retighten the screws.
NOTE:  Do not close so much as to cause a sooty flame. 
Improper adjustment can cause sooting in the firebox and/or 
on the outside of a house with a horizontal termination.
After adjustment, tighten nut to lock in place.
K.   Glass Replacement
1.  Turn off gas to appliance.
2.  Remove door from the appliance and set on a protec-
tive surface.
3.  Remove door crown. See instructions in this manual 
for installation of door crown for procedure.
4.  Remove top and bottom retainer screws from front of 
door. Set top and bottom glass retainers aside. Loosen 
side glass retainer screws, but do not remove.
5.  Remove glass pieces and discard. Keep aluminum 
channels for reassembly.
6.  Slide replacement side glass into the side glass retain-
ers.
7.  Place aluminum channels over side glass.
Install center glass into aluminum channels.
9.  Reinstall glass retainers and screws.
10.  Reinstall door crown. 
 
 
NOTE:  Glass can be replaced either as three separate pieces, 
or as an assembly with the door.  See Section 12.
To Replace Separate Glass Pieces
Use only Door Assembly replacement as specifi ed in Section 
12 of this manual, available from your dealer, if any glass 
becomes broken in the Hudson Bay. 
Follow the previous instructions to install the door crown and 
grille to the new Door Assembly.
Door Frame with Glass Assembly Replacement
Handle glass assembly with care.
CAUTION
•  Inspect the gasket to ensure it is undamaged.
•  Inspect the glass for cracks, chips or 
scratches.
•  Do NOT strike, slam or scratch glass.
•  Do NOT operate appliance with glass door 
removed, cracked, broken or scratched.
•  Replace glass assembly as a complete 
assembly.
OPEN
CLOSE