Listing and Code Approvals
The product is listed to ANSI standards for “Vented Gas Ap-
pliance Heaters” and applicable sections of “Gas Burning 
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles” and "Gas Fired Appliances for use at High 
Altitudes". 
A.  Appliance Certifi cation
B.  Glass Specifi cations
NOTE:  This installation must conform with local codes. In the 
absence of local codes you must comply with the 
National 
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. 
and the 
CAN/CGA B149 Installation Codes in Canada.
D.  High Altitude Installations
Omni-Test Laboratories listed gas appliances are tested and 
approved without requiring changes for elevations from 0 to 
2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000 
feet, it may be necessary to decrease the input rating by 
changing the existing burner orifi ce to a smaller size. Input 
rate should be reduced by 4% for each 1000 feet above a 
2000 foot elevation in the U.S.A.  If the heating value of the 
gas has been reduced, these rules do not apply. To identify 
the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in 
Canada), check with local authorities.
C.  BTU Specifi cations
This appliance is equipped with 5mm ceramic glass.  Replace 
glass only with 5mm ceramic glass.  Please contact your 
dealer for replacement glass.
WARNING
Do NOT use this appliance if any part has been under water. 
Immediately call a qualifi ed service technician to inspect 
the unit and to replace any part of the control system and 
any gas control which has been under water.
Manufactured Home or Mobile Home installation may occur 
only after the home is site located and must conform with 
the Manufactured Home Construction and Safety Standard, 
Title 24 CFR, Part 3280, or, when such a standard is 
not applicable, the Standard for Manufactured Home 
Installations, ANSI/NCSBCS A225.1, or Standard for Gas 
Equipped Recreational Vehicles and Mobile Housing, CSA 
Z240.4.
When installed, the appliance must be electrically grounded 
in accordance with local codes or, in the absence of local 
codes, with the National Electrical Code, ANSI/NFPA 70, or 
the Canadian Electrical Code, CSA C22.1.
* Thermal effi ciency maximum pipe with blower on.
** Canada minimum pipe.
Materials that are reported as passing ASTM E 136, 
Standard Test Method for Behavior of Materials in a Vertical 
Tube Furnace at 750°C, shall be considered non-combustible 
materials.
Materials made of or surfaced with wood, compressed 
paper, plant fibers, plastics, or other materials that can ignite 
and burn, whether flame proofed or not, or whether plastered 
or unplastered shall be considered combustible materials.
E.   Non-Combustible Materials
F.   Combustible Materials
Model
(US or Canada)
Maximum 
Input 
BTU
Minimum 
Input 
BTU
Orifi ce 
Size
(DMS) 
*Steady 
State 
Effi ciency 
%
**P.4
%
Hudson Bay 
(NG)
42,000
28,000
.125
84.02
64.03
Hudson Bay
(LP)
40,500
31,000
.076
85.71
65.43
MODEL:
Hudson Bay
LABORATORY: OMNI Test Laboratories, Inc.
061-S-29b-5
TYPE:
Direct Vent Gas Heater
STANDARD:
ANSI Z21.88-2002
ּ
CSA 2.33-2002
ּ
 
 
UL307b
ּ
CAN/CBA 2.17-M91
G. Electrical Codes
NOTICE:  This appliance must be electrically wired and 
grounded in accordance with local codes or, in the absence 
of local codes, with 
National Electric Code ANSI/NFPA 70-
latest edition or the Canadian Electric Code CSA C22.1.
•  A 110-120 VAC circuit for this product must be protected with 
ground-fault circuit-interrupter protection, in compliance with 
the applicable electrical codes, when it is installed in locations 
such as in bathrooms or near sinks.