Hearth & Home Technologies 8300 Benutzerhandbuch

Seite von 43
HearthStone Quality Home Heating Products Inc
                                                                   Champlain 
Model #8300
 
 
8
O
WNER
I
NFORMATION
 
The installation must conform with local 
codes or, in the absences of local codes, the 
current National Fuel Gas Code, ANSI Z223.1 
(NFPA 54) or CAN/CGA B149 Installation 
Code.  (Installer l’appareil selon les codes ou 
règlements locaux, ou, en l’absence de tels 
règlements, selon les Codes d’installation 
CAN/CGA-B149.)
Do not use this appliance 
if any part has been under water.  
Immediately call a qualified service 
technician to inspect the heater and to 
replace any part of the control system and 
gas control that has been under water.
  (Ne 
pas se servir de cet appareil s’il a été plongé 
dans l’eau, complètement ou en partie.  
Appeler un technicien qualifié pour inspector 
l’appareil et remplacer toute partie du système 
de contrôle et toute commande qui ont été 
plongés dans l’lau. 
 
L
IGHTING 
I
NSTRUCTIONS
 
NOTE: 
The gas control knobs and the piezo 
ignitor are located behind the control valve 
access door, under the front of the unit. 
1.  STOP! Read the  What To Do If You 
Smell Gas! Warning (on the cover of 
this manual). 
2.  Set the on/off/T-stat switch or thermostat 
       to the “OFF” position.          
3.  Push in and turn gas control knob 
clockwise to “OFF”.   (If not previously 
lit, the knob should be in this position.)
 
4.  Wait (5) five minutes to clear out any 
gas.  If you then smell gas, STOP!  Smell 
all around the appliance area for gas. 
Be sure to smell next to the floor because 
some gases are heavier than air and will 
settle on the floor. If you smell gas 
immediately follow the  What To Do If 
You Smell Gas! 
warning on the cover of 
this Manual.
 If you do not smell gas, 
proceed to the next step. 
 
5.  Turn gas control knob counter-clockwise 
to “PILOT”. 
6.  Push in control knob all the way and 
hold in. Immediately light the pilot with 
the gas lighter (push in and “click” the 
piezoelectric spark ignitor button several 
times until lit). Continue to hold the 
control knob in for about 20 seconds 
after the pilot is lit. Release the knob and 
it will pop back out. Pilot should remain 
lit.  If the pilot goes out, repeat the 
operation. 
 
• 
If knob does not  pop out when released, 
stop, shut off the gas supply to the heater 
and immediately call a qualified service 
technician or gas supplier. 
 
• 
If the pilot will not stay lit after several 
tries, turn the gas control knob “OFF” 
and call a qualified service technician or 
gas supplier. 
 
7.  After the pilot lights, turn gas control 
knob counter-clockwise to “ON”. 
8. 
If the ON/OFF/THERMOSTAT switch 
is set to “ON”, the stove should now be 
lit. If the thermostat (or remote) has been 
installed, set the ON/OFF 
THERMOSTAT switch 
to 
“THERMOSTAT” and turn the 
thermostat (or remote) to “ON”. Then 
set the desired temperature.
 
9.  Shut the gas control valve access door. 
 
NOTE
When pressing/clicking the  
piezoelectric spark ignition button to light 
the pilot, watch through the glass (front) of 
the unit. Click the ignitor button until a 
flame is visible at the pilot. Once the pilot is 
lit, continue to press on the gas control knob 
for another 20 seconds, then release. 
Ascertain that the pilot is still lit by looking 
through the front door. If lit, then turn the 
gas control knob fully counter-clockwise to