Seite von 24
26678 Rev H
10
02-02
GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
d. Rock Wool Placement
The  log  set  is  shipped  in  place.  Tear  the  rock
wool  into  pieces  no  larger  than  1/2”  diameter.
Place the rock wool in front of the flange located
in the middle of the burner. Do not place the rock
wool  behind  or  above  the  3/8”  flange.  This  will
block the air slot and cause carbon desposits on
the log. Place the rock wool on both the left and
right sides to complete the burning ember look. It
is  not  necessary  to  use  the  entire  bag.  See
Figure 17.
Figure 17 - Rock Wool Placement
e. Glass Frame Installation
1) When  cleaning  the  glass,  use  only  non-
caustic,  non-abrasive  cleaners.  DO  NOT
ATTEMPT  TO  CLEAN  HOT  GLASS.  It  is
dangerous,  and  the  glass  is  more  likely  to
be stained  by  the  cleaning  agent.  Stubborn
film can often be removed using Brasso® or
a  non-abrasive  cleaner.
2) After cleaning the glass, position the tabs on
the glass frame into the slots on the column
of  the  appliance.  Hold  door  in  place  and
secure  with  screws  removed  earlier.  Be
careful not to over-tighten.
Note: 
Placement of the rock wool should be done
with care and time, as this will create the look of
the fire when burning.
WARNING!
Never operate this appliance with the glass removed
or not sealed.
WARNING!
Do not operate appliance with the panel(s) removed,
cracked  or  broken.  Replacement  of  the  panel(s)
should be done by a licensed or qualified service
person.
f.
Brass Trim Cleaning
All prints and smudges must be wiped clean from
the  brass  trim  prior  to  initial  burn.  If  this  is  not
done,  these  prints  will  be  cured  into  the  brass
finish and set for the life of the appliance. To keep
the finish looking its best, gently wipe with a soft
cloth after the appliance has had ample time to
cool down. If desired, use a non-abrasive cleaner
such as soap and water. Never use any solvent,
thinner  or  abrasive  cleaner  since  these  will
damage  the  finish.
g. Valve Access
The  valve  is  located  behind  the  control  access
panel. Lift the panel up and rotate forward. See
Figure 18. This will expose the gas valve, variable
regulator and fan control, as shown in Figure 19.
Figure 18 - Valve Access
Figure 19 - Gas Valve, Variable Regulator & Fan Control