Hearth & Home Technologies GBI25 Benutzerhandbuch

Seite von 24
02-02
13
26678 Rev H
GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
Figure 25 - Wiring Diagram
Note: 
The fan will not turn on until the appliance has
reached  its  proper  operating  temperature.  This  is
determined by a thermal disc in the fan assembly. Also,
the fan will continue to run until the appliance has cooled
sufficiently  after  shutdown.
WARNING!
Keep the area near the appliance clear and free from
combustible  materials,  gasoline  and  other  flam-
mable vapors and liquids.
Note:
 The ON/OFF switch now becomes inoperable.
b. Optional Wall Thermostat
The  use  of  a  millivolt  thermostat  is  allowed.  It
must be located within 20 feet of the appliance.
Figure 25 shows how to connect the thermostat.
Remove ON/OFF switch wires from valve. Place
thermostat  wires  to  the  posts  marked  TH  and
TH/TP.
5. PRE-USE  CHECKLIST
Use the following checklist as a guide to be sure your
installation  is  correct  and  complete
•
Operating  instructions  have  been  read  and
understood.
•
All safety warnings have been read and followed.
•
Flex  liners  and  termination  cap  are  properly
installed
•
Logs and rock wool have been placed correctly.
•
All fittings are tight and there are no gas leaks.
•
Glass  is  in  proper  position  and  sealed.
•
Prints  and  smudges  are  wiped  from  brass  trim.
•
Check  air  shutter  adjustment.