2700-I  WOOD INSERT (ACT)
CLEANING pLATED SURFACES
IMpORTANT:  You must clean all the fingerprints and oils 
from the plated surfaces before firing the insert for the first 
time. Use warm soapy water and a soft rag, glass cleaner 
and a paper towel, or vinegar and a paper towel to remove 
the  oils.    DO  NOT  use  abrasive  cleaners!  If  not  cleaned 
properly prior to lighting the first fire, the oils can cause per-
manent stains.  The plating will be cured upon firing of the 
insert and oils will no longer affect the finish.  Subsequently, 
little maintenance is then required.  Wipe clean as needed 
with a soft towel. 
GLASS REpLACEMENT INSTRUCTIONS
Replace with 5mm ceramic glass only
1.  Remove door from insert and lay on a padded flat surface.
2.  Remove glass retainer screws using a Phillips screw driver.
.  Lift glass out of the door frame and/or side frames.
4.  Lay  new  glass  with  fiberglass  tape  around  it  into  door 
frame and/or side frames.
5.  Place  glass  retainers  over  the  fiberglass  tape  on  the 
edges of the glass and re-install screws.  Be sure glass 
is  centered  in  the  opening  (i.e.  same  space  top  and 
bottom, left and right).
6.  Tighten screws enough to hold frame and glass in place.
7.  Check again for centering of glass in door and/or side 
frames and give all screws a final tightening.
Quadra-Fire inserts are equipped with super heat resistant 
ceramic glass which can only be broken by impact or misuse.  
Clean glass with any non-abrasive glass cleaner.  Abrasive 
cleaners  may  scratch  and  cause  glass  to  crack.    Inspect 
glass regularly.  If you find a crack or break, immediately put 
the fire out and return the door to your authorized dealer for 
replacement of glass before further use.  Do not substitute 
materials for glass replacement.
MAINTENANCE
GLASS CLEANING
Handle glass assembly with care.
When cleaning glass:
•  Avoid striking, scratching or 
slamming glass.
•  Do NOT clean glass when hot.
CAUTION
•  Do NOT use abrasive cleaners.
•  Use a hard water deposit glass cleaner on white film.
•  Use commercial oven cleaner on heavier deposits.
•  Remove all residue of oven cleaner or will permanently 
stain glass on next firing.
•  Refer to maintenance instructions.
Glass 
Assembly
  CREOSOTE (CHIMNEy) CLEANING
Fire Risk.
•  Do not use chimney cleaners or flame colorants 
in your appliance.
Will corrode pipe.
WARNING
Remove all ash from the firebox and extinguish all hot embers 
before  disposal.  Allow  the  appliance  to  cool  completely.  
Disconnect flue pipe or remove baffle and ceramic blanket from 
appliance before cleaning chimney.  Otherwise residue can pile 
up on top of the baffle and ceramic blanket and the appliance 
will not work properly.  (See Baffle Removal on 
page 20).  Close 
the door tightly.  The creosote or soot should be removed with 
a  brush  specifically  designed  for  the  type  of  chimney  in  use. 
Clean out fallen ashes from the firebox. A chimney sweep can 
perform this service.  
It is also recommended that before each heating season the 
entire system be professionally inspected, cleaned and repaired 
if necessary.
I
nspection:  Inspect the system at the appliance connection 
and at the chimney top.  Cooler surfaces tend to build creosote 
deposits quicker, so it is important to check the chimney from 
the top as well as from the bottom.
Formation and  Need  For  Removal:   When  wood  is  burned 
slowly, it produces tar and other organic vapors which combine 
with expelled moisture to form creosote.  The creosote vapors 
condense in the relatively cool chimney flue of a newly-started or 
a slow-burning fire.  As a result, creosote residue accumulates on 
the flue lining.  When ignited, this creosote creates an extremely 
hot fire which may damage the chimney or even destroy the 
house.  The chimney connector and chimney should be inspected 
once every 2 months during the heating season to determine 
if a creosote or soot buildup has occurred.  If creosote or soot 
has accumulated, it should be removed to reduce the risk of a 
chimney fire.
If your type of installation is direct connect within a masonry 
chimney, the insert will need to be pulled out from the fire-
place and disconnected from the flue prior to cleaning the 
chimney.  The creosote can either be caught in a large gar-
bage bag secured to the pipe or swept and vacuumed out 
of the fireplace.  Reconnect the pipe and re-install the insert 
following installation instructions in this manual.
Fire Risk.
Prevent creosote buildup.
WARNING
•  Inspect chimney connector and chimney once every two 
months during heating season.
•  Remove creosote to reduce risk of chimney fire.
•  Ignited creosote is extremely HOT.