Sanyo CH3632 Benutzerhandbuch
4. Service procedures
1
2
3
4
Section
– 71 –
SM830076
(6)
Procedures When a Specific Component Does Not Work
1)
Indoor fan does not operate.
No
Yes
Is fan motor capacitor
normal ?
normal ?
Is there voltage output
of P.C.B. Ass'y for fan
motor ?
of P.C.B. Ass'y for fan
motor ?
• Check resistance of
fan motor winding.
fan motor winding.
Replace the fan motor.
Replace the capacitor.
Replace the P.C.B. Ass'y
in the indoor unit.
in the indoor unit.
No
Yes
Out
0650_M_S
2)
Flaps in indoor unit’s air outlet does not operate, when you press SWEEP button.
Is 2P connector socket (WHT)
attached to panel
connected firmly with 2P plug ?
attached to panel
connected firmly with 2P plug ?
No
Yes
Replace P.C.B. Ass'y in the
indoor unit.
indoor unit.
Yes
No
Replace the motor.
Connect firmly.
Check the louver motor resistance.
Is auto louver motor normal?
Is auto louver motor normal?
1200_M_S