Daewoo DPB-280LH Benutzerhandbuch

Seite von 51
36
7. TROUBLE SHOOTING
Outdoor unit does
not run?(note. 1)
Does
the compressor run
normally?
Indoor unit does
not run(note 1)
Check the failure
code according to
the self diagnostic
(note  2)
Is the unit 
display
mormal?
check the failure 
code according to
the self-diagonostic
(note 2)
Normal
check the 
connecting
point of
magnetic
contactor
YES
YES
YES
YES
NO
NO
YES
Trouble
Is the power
applied to the
unit
Is the 
power normal?
check the voltage between
L & N of terminal
block
press the power ON/OFF 
button on remote controller
Does the 
beeper beep two
times?
Is the display
all off?
• Check the connector on display
PCB connected to control PCB
• Check the display PCB itself
Check power supply mains
or interconnection wires
Check the wiring of indoor
Does 
control PCB 
status LED repeat one 
second "on and 
off"?
• control PCB fault
• Micom or reset 
IC fault
• Check the remote signal receiver
• Check the connection between signal
receiver and control PCB
YES
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
Is the
unit display
normal?