York YZH024 THRU 060 Benutzerhandbuch

Seite von 28
4
Unitary Products Group
345094-YTG-D-0108
COOLING CAPACITY - With Air Handler Coils
UNIT 
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
W
STAGE
RATED 
CFM
NET MBH
SEER
EER
TOTAL
SENSIBLE
18 SEER HP WITH MV - VARIABLE SPEED
YZH02411
MV12B 17  FC/MC43B 
1
645
18.2 13.5 
16.40 
14.00 
2 835 23.6  18.8 
13.60 
MV12D 24  FC/MC48D 
1 645 18.5  14.0 
17.00 
14.50 
2 835 24.0  19.5 
14.00 
MV12D 24  FC/MC60D 
1 645 18.5  14.0 
17.00 
14.50 
2 835 24.0  19.5 
14.00 
YZH03611
MV16C 21  FC/MC43C 
1 775 24.8  18.2 
17.10 
14.20 
2 1200 35.4  26.6 
13.10 
MV16C 21  FC/MC48C 
1 775 25.0  18.6 
17.30 
14.40 
2 1200 35.8  26.8 
13.35 
MV12D 24  FC/MC48D 
1 845 24.8  18.0 
17.35 
14.45 
2 1245 35.2  26.2 
13.35 
MV12D 24  FC/MC60D 
1 845 24.8  18.3 
17.50 
14.60 
2 1245 35.4  26.4 
13.35 
MV12D 24  FC/MC62D 
1 845 25.6  19.7 
18.00 
15.00 
2 1245 36.0  27.8 
13.35 
YZH04811
MV16C 21  FC/MC48C 
1 1000 33.4  25.0 
16.65 
13.60 
2 1600 46.5  35.6 
12.20 
MV20D 24  FC/MC48D 
1 1045 33.4  25.0 
16.30 
13.35 
2 1570 46.5  35.6 
12.05 
MV20D 24  FC/MC60D 
1 1045 33.0  25.0 
16.20 
13.25 
2 1570 47.0  36.4 
12.25 
MV20D 24  FC/MC62D 
1 1045 33.8  25.8 
17.00 
13.90 
2 1570 47.0  36.6 
12.50 
YZH06011
MV20D 24  FC/MC60D 
1 1175 39.5  27.6 
14.75 
12.20 
2 1820 57.0  42.0 
11.35 
MV20D 24  FC/MC62D 
1 1175 41.0  29.8 
15.50 
12.80 
2 1820 57.0  43.0 
11.80 
18 SEER HP WITH AV/SV - VARIABLE SPEED
YZH02411
AV36 21 
-
1 600 18.1  13.5 
16.65 
14.20 
2 765 23.4  18.5 
13.70 
YZH03611
AV36 21 
-
1 830 25.2  19.0 
17.45 
14.55 
2 1270 35.4  27.4 
13.40 
AV/SV48 24 
-
1 910 25.8  20.4 
17.65 
14.70 
2 1190 35.4  27.0 
13.60 
YZH04811
AV/SV48 24 
-
1 1135 34.0  26.4 
16.75 
13.70 
2 1610 47.0  36.4 
12.30 
AV/SV60 24 
-
1 1085 33.6  26.0 
16.55 
13.55 
2 1655 47.0  37.0 
12.30 
YZH06011
AV/SV60 24 
-
1 1145 40.5  29.0 
15.15 
12.50 
2 1765 56.5  41.5 
11.50 
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.