Runco SC-30d/SC-35d Installation/Operation Manual
107 
PRE
L
IMINAR
Y
• 11 = Password not entered
www indicates the command code. This field is case insensitive; for example, PWR, pwr 
and 
PwR are all equivalent.
:x is the destination parameter.  This is an optional parameter that indicates which 
memory the command is referencing.  This parameter is reserved for future use.
z is the new value (for Set, Increment or Decrement commands) or the current value 
(for Get commands) for this parameter.  It can have one of two formats:
• Integer value: Any positive or negative number; for example, 
100. 
• String value: Any string surrounded by double quotes; for example, 
“This is a 
string.”
[CR] is the ASCII carriage return key (0x0D).
Command and Response 
Examples
Here are some examples of serial commands and their responses:
Serial Command List
Table 6-1 lists all supported commands. 
Command
Command Data
Response
Power query when 
unit is powered on
(PWR?) [CR]
(0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR]
(0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR]
(0;BRT=25) [CR]
Invalid command 
(ZZZ=0) [CR]
(1;ZZZ=0) [CR]
Invalid parameter 
(received string, 
expected integer) 
(CON=”Some string”) 
[CR]
(9;CON=”Some string”) 
[CR]
Table 6-1. Serial Commands
Setting
Command 
Code
Read/
Write
Inc/
Dec
Min 
Value
Max 
Value
String?
Notes
PCE Auto Color Enable
AAC
R/W
No
0
1
No
0 = Off; 1 = On
PCE Diagnostic Color
AAD
R/W
No
0
6
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
PCE Blue x
ABX
R/W
Yes
-100
100
No
PCE Blue y
ABY
R/W
Yes
-100
100
No
Adjustment Mode
ADJ
R/W
No
0
2
No
0 = Both
1 = Left
2 = Right
PCE Green x
AGX
R/W
Yes
-100
100
No
PCE Green y
AGY
R/W
Yes
-100
100
No