Runco RS-900 Series RS1100 Series Betriebsanweisung

Seite von 104
68
RS-900 and RS1100 Series Installation/Operation Manual
PRE
L
IMINAR
Y
Changing either or both of these numbers changes the hue of the color and relocates 
the “triangle” for possible colors. For example, changing the x/y coordinates for red 
moves the color closer to either orange or violet, which in turn affects all displayed 
colors having a red component.
To adjust the gamut:
1.
Select Gamut from the Advanced Options menu and press ENTER
2.
To do an automatic gamut adjustment, highlight “Enter” and press ENTER. If further 
calibration is necessary, continue with the next step. 
3.
Highlight “Settings” and press 
 or 
 to select “Manual.” 
4.
Highlight “White” and press ENTER. The RS-900/RS1100 displays a white field on 
the screen. 
5.
Using the color analyzer, measure the x and y coordinates for about 15 seconds. 
Make a note of the results. 
 
6.
Press EXIT or ENTER.
7.
Highlight “White” and press 
.
8.
Press ENTER to select the first digit of the x coordinate value for White (obtained in 
Step 5).
9.
Press 
 or 
 repeatedly to set the digit.
10. Press 
 to select the next digit; use the 
 and 
 buttons to change it.
11. Repeat Step 10 for the third digit.
12. Press ENTER
13. Press 
 to highlight the “y” coordinate value for White. Then, press ENTER to select 
the first digit. 
14. Repeat Steps 9 through 12 to set the “y” coordinate value for White. 
15. Press 
 to highlight the “Y” coordinate value. Then press ENTER to select the first 
digit. 
16. Repeat Steps 9 through 12 to set the “Y” coordinate value for White. 
17. Press EXIT.
18. Repeat Steps 4 through 17 for Red, Green, Blue and D. White (Desired White). 
19. Highlight “Save” and press ENTER
To undo the effects of a previous calibration, highlight “Settings” and press 
 or 
 to 
select “Default.” 
Reset to Defaults: To restore the ISF default image settings for the current input source 
ONLY, select Reset to Defaults and press the 
 button to highlight “Yes.” Then, press 
ENTER.
To perform these adjustments, you will need a color analyzer (Sencore 
ColorPro 5000 software and ColorPro III sensor, or equivalent). 
Note
Settings
Manual
White
x:312
y:329 Y:045
Red
x:640
y:330 Y:015
Green
x:300
y:600 Y:022
Blue
x:150
y:060 Y:018
D. White x:312
y:329 Y:045
Enter
Save
Color Temp.
6500
White
x:000