Runco SC-30d Benutzerhandbuch

Seite von 156
68
Runco SC-30d/SC-35d Installation/Operation Manual
PRE
L
IMINAR
Y
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an 
acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2 shows a typical PLUGE 
pattern.
Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness
PLUGE patterns vary but generally consist of some combination of black, white and gray 
areas against a black background. The example above includes two vertical bars and four 
shaded boxes.
Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:
• The darkest black bars disappear into the background. 
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the 
one shown in Figure 4-3. 
Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast and press ENTER. Adjust the contrast to a point just below which the 
white rectangle starts to increase in size.
Brightness and contrast controls are interactive. A change to one 
may require a subtle change to the other in order to achieve the 
optimum setting. 
Below Black
Above Black
Note