INSTALLATION
When Installing this Product…
1. Read these instructions carefully. Failure to follow them 
could damage the product or cause a hazardous condi-
tion.
2. Check the ratings given on the product to make sure the 
product is suitable for your application.
3. Installer must be a trained, experienced service techni-
cian.
4. After installation is complete, check out product opera-
tion as provided in these instructions.
CAUTION
Hazardous Voltage.
Can damage heating/cooling system.
1.
Disconnect power supply before beginning instal-
lation to prevent electrical shock or equipment 
damage.
2.
Do not short across coil terminals on relay. This 
can burn out thermostat heat anticipator.
3.
To prevent interference with the thermostat link-
age, keep wire length to a minimum and run wires 
as close as possible to the subbase. 
4.
Do not overtighten thermostat captive mounting 
screws because damage to subbase threads can 
result.
IMPORTANT
An incorrectly leveled thermostat will cause the tem-
perature control to deviate from setpoint. It is not a 
calibration problem.
Location
Install the thermostat about 5 ft (1.5m) above the floor in an 
area with good air circulation at average temperature.
Do not mount the thermostat where it can be affected by:
— drafts or dead spots behind doors, in corners or under 
cabinets.
— hot or cold air from ducts.
— radiant heat from the sun, fireplace, or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall behind 
the thermostat.
Mount Subbase
The subbase can be mounted on a vertical outlet box, 
horizontal outlet box or directly on the wall.
1. If the subbase is mounted on a vertical outlet box, order 
Honeywell part no. 193121A Adapter Assembly. See 
Fig. 4. The assembly includes an adapter ring, two 
screws and a cover plate to cover marks on the wall. 
Install the ring and cover plate on the vertical outlet box.
NOTE: For a wall installation, hold subbase in position and 
mark holes for anchors. See Fig. 5. Wall anchors 
must be obtained from local hardware store. Be care-
ful that the wires do not fall back into the wall open-
ing. Set aside subbase. Drill four 
3/16 in. (4.8 mm) holes and gently tap anchors into 
the holes until flush with the wall.
2. Pull wires through the cover plate (if used) and subbase 
cable opening. See Fig. 6.
3. Secure the cover plate (if used) and subbase with the 
screws provided. Do not fully tighten the subbase 
screws.
Level the subbase using a spirit level, see Fig. 7, and firmly 
tighten subbase mounting screws. The subbase mounting 
holes provide for minor out-of-level adjustments.
Fig. 4. Installing Q674 Subbase on outlet box.
M6009
VERTICAL 
OUTLET
BOX
ADAPTER
RING
COVER 
PLATE
MOUNTING
SCREWS (2)
1
SUBBASE
SUBBASE
MOUNTING  SCREWS (2) 
HORIZONTAL
OUTLET
BOX
1
2
2
1    NOT INCLUDED WITH UNIT.
2    ACCESSORY PART AVAILABLE (193121A).
THERMOSTAT
CAPTIVE
MOUNTING SCREWS (2)
50    60    70    80
50    60    70    80
HEAT
COOL
THERMOSTAT 
COVER
50    60    70    80