Honeywell T822 Benutzerhandbuch

Seite von 16
T822/T827 Series • Owner's Manual
69-2251EFS—01 
2
System Types
•  Gas or oil
•  Warm air, hot water, high-efficiency furnaces, heat pumps, steam, gravity
•  Normally closed hot water valves (T822K)
•  2-wire cooling systems (T822L)
•  Normally open hot water valves (T822L)
System Settings
•  Heat, Off (select models only)
Fan Settings
•  Auto, On (select models only)
Specifications
Temperature Control Range
•  45° to 95°F (7° to 35°C)
•  35° to 85°F (2° to 29°C)*
Operating Ambient Temperature
•  0° to 120°F (-18° to 49°C)
Operating Relative Humidity
•  5% to 90% (non-condensing)
Dimensions (vertical model)
•  2.88W x 4.75H x 1.5D (inches)
•  73W x 121H x 38D (mm)
Dimensions (horizontal model)
•  4.75W x 2.88H x 1.5D (inches)
•  121W x73H x 38D (mm)
Product application
This thermostat provides control of:
•  24 Vac heating systems (T822K)
•  750 mV or 12 Vdc heating systems (T827K)
•  24 Vac cooling systems (T822L)
Electrical Ratings
Terminal
Voltage (50/60Hz)
Running Current
W
1
 Heating
20-30 Vac
0.02-1.2 A
(Powerpile)
750 mVdc
100 mAdc
(DC Powered)
12 Vdc
.55 A
Y
2
 Cooling
20-30 Vac
0.02-1.2 A
G  Fan
20-30 Vac
0.02-0.6 A
(Normally open hot water valve.)
20-30 Vac
0.02-1.2 A
1
 T822K and T827K
2
 T822L
*  CAUTION: Do not use a product
with this temperature control range 
in a home. Temperatures at or below 
freezing can occur. A product with this 
temperature range is for use in areas 
where temperatures below freezing can 
occur, such as a garage.