Honeywell CM900 Benutzerhandbuch

Seite von 12
4
CM900 Wireless - Programmable Room Thermostat
2.2 Installing the Room Thermostat
2.2.1 Power Up
1.
  Remove  the  battery  cover  and  insert  the  batteries  supplied  with  the  room  thermostat  (2  x  AA  LR6 
Alkaline Batteries).
2.
  On the initial power up the available user interface languages will be displayed (only on certain models). 
Use the     or   buttons to cycle through the options until the desired language is displayed. Press the 
green   button to confirm the selection.
3.
  Set the slider switch to the DATE mode.
4.
  Use  the      or    buttons  to  set  the  correct  day  /  month  /  year,  pressing  the  green    button  to 
confirm.
5.
  Use the     or   buttons to set the correct time, pressing the green   button to confirm.
2.2.2 RF Communication Check (Test Mode)
To check the RF communication, hold the room thermostat about 2-3 metres from the installed Relay Box. 
Move the slider on the room thermostat to the OFF position then press the     and   buttons together 
with the   button for 3 seconds. The unit will display ‘TEST TRANSMIT’ and it will send test signals to the 
Relay Box, flashing the green LED on every 6 seconds (relay output will remain off) for a maximum of 10 
minutes. When the green LED flashes on every 6 seconds proceed to the next step.
NOTE: 
If the green LED is not switched at specified intervals, the red LED is flashing or if you are installing 
a replacement Relay Box or room thermostat, follow the procedures described in section 5.1 Binding / 
Rebinding Procedure
.
Install the batteries (included) and attach the instruction label to flap