69-1199—2
8
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call 
your local heating/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the 
old thermostat (see illustration).
Match the letter of your old thermostat wire with the 
corresponding terminal letter on your new thermostat. Refer to 
Table 2.
Remove the factory-installed jumper connecting terminals R and 
RC if wires are connected to both of those terminals.
For wiring diagrams, if needed, see pp 21-22.
Loosen the terminal screws. Slip each wire beneath its matching 
terminal. Wraparound and straight connections are both 
acceptable, (see illustration). Tighten the terminals.
Plug the hole in the wall with insulation to help prevent drafts 
from adversely affecting thermostat operation.
M16425