Type 99 Pressure Reducing Regulators
Introduction
Scope of the Manual
This manual describes and provides instructions and 
parts lists for Type 99 pressure reducing regulators 
complete with standard P590 Series integral filter.  
However, complete instructions and parts listing for the 
Type 1301F pilot supply regulator, and other Fisher
®
 
equipment, such as monitoring pilots will be found in 
separate instruction manuals.
Description
The Type 99 gas regulators provide a broad capacity 
for controlled pressure ranges and capacities 
in a wide variety of distribution, industrial, and 
commercial applications.
A Type 99 regulator has a Type 61L (low pressure), 
Type 61H (high pressure), or a Type 61HP (extra 
high pressure) pilot integrally mounted to the actuator 
casing as shown in Figure 1.  The Type 99 regulator 
can handle up to 1000 psig (69,0 bar) inlet pressures 
(the 1000 psig (69,0 bar) regulator requires a 
Type 1301F pilot supply regulator and a Type H110 pop 
relief valve).  The pilot supply regulator reduces inlet 
pressure to a usable 200 psig (13,8 bar) for the extra 
high pressure pilot.  This regulator comes standard with 
O-ring seals on the guide bushing and valve carrier 
(key 26, Figure 7) to keep main valve body outlet 
pressure from interfering with outlet pressure in the 
lower casing assembly (key 29, Figure 9).
Specifications
!
WaRnIng
Since a pilot-operated regulator is 
constructed of both a pilot and a main 
valve, care should be used not to exceed 
the maximum inlet pressure shown on 
the nameplate of either unit.  When inlet 
pressure exceeds the pilot limitation, a 
pilot supply reducing regulator and/or 
relief valve will be required.
Specifications and ratings for various Type 99 
constructions are listed in the Specifications section 
on page 2.  Some specifications for a given regulator 
as it originally comes from the factory are stamped 
on nameplates located on the pilot and actuator 
spring cases.  A tag (key 159, Parts List) additionally 
may be installed on the pilot to indicate a regulator 
with O-ring stem seal.  These regulators and their 
installations should be checked for compliance with 
applicable codes.
Figure 1.  Type 99 Regulator with Type 61H (high pressure) Pilot
W2676