Sony PDW-R1 Benutzerhandbuch

Seite von 155
Chapt
er
 4   
Re
c
o
rdin
g/
Pla
y
ba
c
k
44
4-1 Recording
4-1-2 Recording Time Code and User Bit Values
There are the following four ways of recording time code:
• Internal Preset mode, which records the output of the 
internal time code generator, set beforehand to an initial 
value. The following run modes can be selected.
- Free Run: Time code advances continually.
- Rec Run: Time code advances only during recording.
• Internal Regen mode, which records the output of the 
internal time code generator, initialized to time code 
following continuously upon the time code of the last 
frame of the last clip on the disc.
• External Regen mode, which records the output of the 
internal time code generator, synchronized to an external 
time code generator. As the external input, the time code 
input to any of the following connectors can be selected.
- TIME CODE IN connector: LTC
- VIDEO IN connector: VITC
-
S400 (i.LINK) connector: TC or VITC
- SDI IN connector: SMPTE RP188 LTC
• External Preset mode, which directly records the input of 
an external time code generator. As the external input, 
the time code input to any of the following connectors 
can be selected.
- TIME CODE IN connector: TC
-
S400 (i.LINK) connector: TC
- SDI IN connector: SMPTE RP188 LTC
As shown in the following table, you can switch between 
different time code recording modes by combining switch 
settings in the time data settings section with the selection 
of a video input signal and settings of extended menu item 
629.
To record time code after setting an initial 
value
Set the following switches beforehand.
• INT/EXT/RP188 switch: INT
• PRESET/REGEN switch: PRESET
• F-RUN/R-RUN switch: F-RUN or R-RUN
See 7-3-2 “Extended Menu Operations” (page 108) for 
more information about how to make extended menu 
settings.
Then set an initial value as described below, and carry out 
recordin(see page 48).
To set an initial value
Proceed as follows.
Time code recording mode
Time data settings section switch
VIDEO INPUT 
SEL button
Item 
629
Reference
INT/EXT/
RP188
PRESET/
REGEN
F-RUN/
R-RUN
Internal Preset Free Run
INT
PRESET
F-RUN
Internal Preset Rec Run
R-RUN
Internal Regen
INT
REGEN
External Regen (TC IN connector: 
LTC)
EXT
REGEN
SDI/
COMPOSITE/
SG
tc
External Regen (VIDEO IN 
connector: VITC)
vitc
External Regen (i.LINK connector: 
TC)
i.LINK
tc
External Regen (i.LINK connector: 
VITC)
vitc
External Regen (SDI IN 
connector: SMPTE RP188 LTC)
RP188
REGEN
SDI
External Preset (TC IN connector: 
TC)
EXT
PRESET
SDI/
COMPOSITE/
SG
External Preset (i.LINK connector: 
TC)
i.LINK
External Preset (SDI IN 
connector: SMPTE RP188 LTC)
RP188
PRESET