Chapter 3. HSC Control Statements and HSC Start Procedure   167
1st ed., 6/30/04 - 312579601
 
Initializing the HSC to the Base Service Level
HSC software can be started to the base service level by adding the BASE parameter on 
the /PARM statement of the startup SLKJCL, this includes specifying it on the ACS INIT 
or ACS SUBMIT commands. When using the CP AUTOLOG command, the BASE 
parameter must be specified on an existing /PARM statement in the startup SLKJCL. The 
BASE parameter can be used with other parameters on the /PARM statement. 
When the BASE parameter is specified in the startup SLKJCL, the syntax to initialize the 
HSC to the base service level is the same as for initializing to the full service level. 
When the BASE parameter is not specified in the startup SLKJCL, the commands used to 
initialize the HSC to the base service level must include a PARM=BASE parameter. 
Syntax for Initializing HSC to Base Service Level
After initializing to this point, the SRVlev command can be used to bring the subsystem up 
to full function.  
 
ACS INIT ( PARM=BASE
  - or -
ACS SUBMIT strtjclfn strtjclft strtjclfm  libclass ( PARM=BASE