StorageTek 312564001 Benutzerhandbuch

Seite von 189
 
140 
DB2 Manager User Guide 
 StorageTek 
Proprietary 
OTD17013 
Retrieval using the specified KEY fields cannot be made via 
INDEXONLY processing 
 Explanation:  Scanning of the table using the key fields specified in the SELECT 
statement in the SQLIN file cannot be performed via index-only 
processing.   Execution of the utility cannot continue, and is 
terminated with a condition code 12. 
 
Action:  Modify the SELECT statement in the SQLIN file to ensure that the 
specified columns are those used to uniquely index a row in the table, 
and re-submit the job. 
 
OTD17014 
Return Code xx, Supp codes X'yyyyyyyy' received during OPEN | 
QUERY | DELETE | CLOSE processing for Archive Manager 
database zzzz 
 Explanation:  An error has been received from an Archive Manager open, query, 
delete or close request.  ‘xx’ gives the return code and ‘yyyyyyyy’ the 
hexadecimal supplementary reason codes received from Archive 
Manager.   Execution of the utility has been terminated with condition 
code 12. 
 
Action:  Refer to the Archive Manager User Manual for a description of the 
return and supplementary codes displayed in the message.  Take the 
appropriate corrective action and re-submit the job.   If no obvious 
reason for the error can be identified, contact your local STK support 
representative. 
 
OTD200xx – control region master processor 
messages 
Messages from the DB2 Manager control region master processor are written to the 
system log. 
 
OTD20000 Enter 
request: 
 Explanation:  This is the operator reply message displayed by the control region 
after successful initialization. 
 
Action:  All DB2 Manager operator commands are entered as responses to 
this message. After processing a command, the control region will 
redisplay this message. 
 
OTD20001 
Error opening parameter file SYSPARM 
 Explanation:  An error has occurred opening the DB2 Manager parameter library 
during initialization  processing.  Initialization is terminated.