11. PROTECTION OPERATION LIST
 Failure
Protection
Operation Indicator
Remedy
Recovery
Overcurrent due 
to overload
Current limiter activated 
when impedance drops 
below the specified 
value. 
Peak indicator lights.  Remove overload.
Connecting a correct load 
automatically restores 
normal operation. 
Short circuit
Current limiter activated. 
Load is disconnected.
Protection indicator 
lights. 
Check speakers and 
lines for short circuit.
Turn off the power switch. 
Correct the load, then 
switch on the power.
Rise in heat sink 
temperature 
(over 110
°C)
Load disconnected.
Protection indicator 
lights.
Temperature rise 
inside the unit 
(over 80
°C)
Built-in amplifier unit 
that caused the failure 
halted.
Four indicators of 
the corresponding 
channel extinguish.
Check the unit for 
correct ventilation and 
overload. 
Operation automatically 
returns to normal when 
the temperature decreases.
Abnormal DC 
 voltage output
Load disconnected.
Protection indicator 
lights.
Contact the TOA dealer where the unit was 
purchased.