Bose MR-J2S- B Benutzerhandbuch

Seite von 172
11 -  7
11. CHARACTERISTICS
Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia
moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the
load inertia moment may exceed the value, contact Mitsubishi.
Servo amplifier
Load inertia moment ratio [times]
MR-J2S-10B to MR-J2S-200B
MR-J2S-10B1 to MR-J2S-40B1
30
MR-J2S-350B
16
MR-J2S-500B
MR-J2S-700B
15
11.4 Encoder cable flexing life
The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed
values, provide a little allowance for these values.
1   10
7
5   10
7
1   10
8
5   10
6
1   10
6
5   10
5
1   10
5
5   10
4
1   10
4
5   10
3
1   10
3
 
a
b
Fl
exi
ng l
if
[t
im
es]
4
7
10
20
40
70 100
200
Flexing radius [mm]
a :  Long flexing-life encoder cable 
      MR-JCCBL   M-H 
      MR-JHSCBL   M-H 
      MR-ENCBL   M-H 
b :  Standard encoder cable 
      MR-JCCBL   M-L 