Bose MR-J2S- B Benutzerhandbuch
1 - 3
1. FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications
Servo Amplifier
MR-J2S-
Item
10B
20B
40B
60B
70B
100B
200B
350B
500B
700B
10B1
20B1
40B1
Voltage/frequency
3-phase 200 to 230VAC, 50/60Hz or
1-phase 230VAC, 50/60Hz
1-phase 230VAC, 50/60Hz
3-phase 200 to 230VAC, 50/60Hz
1-phase 100 to
120VAC 50/60Hz
120VAC 50/60Hz
Permissible voltage
fluctuation
fluctuation
3-phase 200 to 230VAC:170
to 253VAC
1-phase 230VAC: 207 to 253VAC
to 253VAC
1-phase 230VAC: 207 to 253VAC
3-phase 170 to 253VAC
1-phase
85 to 127VAC
85 to 127VAC
Permissible frequency
fluctuation
fluctuation
Within 5%
P
ow
er
s
uppl
y
Power supply capacity
Refer to Section 11.2
System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), servo motor overheat protection, encoder fault protection, regenerative fault protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
relay), servo motor overheat protection, encoder fault protection, regenerative fault protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Structure
Self-cooled, open (IP00)
Force-cooling, open (IP00)
Self-cooled,
open(IP00)
[ ] 0 to 55 (non-freezing)
Operation
[ ] 32 to 131 (non-freezing)
[ ]
[ ]
20 to 65 (non-freezing)
Ambient
temperature
temperature
Storage
[ ]
4 to 149 (non-freezing)
Operation
Ambient
humidity
humidity
Storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
5.9 [m/s
5.9 [m/s
2
] or less
En
vi
ro
nm
en
t
Vibration
19.4 [ft/s
2
] or less
[kg] 0.7
0.7
1.1
1.1
1.7
1.7
2.0
2.0
4.9
7.2
0.7
0.7
1.1
Weight
[lb] 1.5
1.5
2.4
2.4
3.75
3.75
4.4
4.4
10.8
15.9
1.5
1.5
2.4