Maintenance Object Repair Procedures 
9-425
CO-DS1 (DS1 CO Trunk) 
9
1020
ABORT
The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log. If 
present, refer to the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Trunk 
Circuit Pack).
2. Retry the command.
2012
ABORT
The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2000
FAIL
Response to the seizure message was not received within the allowable 
time period.
1. Enter the list configuration board UUCSS command. If the circuit 
pack is a TN767B vintage 8 or 9, a failure of test 314 causes a 
subsequent failure of test 7 due to a firmware bug. Eventually, the 
board and all of its ports will be taken out of service and extraneous 
on-board alarms will be generated. Replace the circuit pack with a 
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If 
present, refer to the DS1-BD (DS1 trunk circuit pack) maintenance 
documentation or to the UDS1-BD (UDS1 trunk circuit pack) 
maintenance documentation.
4. Retry the command at 1-minute intervals for a maximum of 5 times.
2053
FAIL
At least one of the following errors was found on the DS1 circuit pack: loss 
of signal (1281), blue alarm (1793), red alarm (2049), yellow alarm (2305), 
or hyperactivity (1537).
1. Look for these error types in the hardware error log and then follow the 
procedures given in the maintenance documentation that is 
appropriate for the error type that was found.
FAIL
The trunk cannot be seized for an outgoing call. This could cause in-line 
failures to be reported against the trunk (no answer would report error type 
257 with auxiliary data 57487 in the error log).
1. Verify the Trunk Type field on the trunk administration screen form 
matches the trunk type administered on far end switch.
2. Look for DS1-BD/UDS1-BD errors in Error Log. If present, refer to 
DS1-BD/UDS1-BD (DS1/UDS1 Trunk Circuit Pack).
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-178.
TEST #314 DS1 CO Dial Tone Seizure Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page