Lucent Technologies Release 7 Benutzerhandbuch

Seite von 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-459
DAT-LINE (Data Line Port) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Digital Looparound Test, for example, you may 
also clear errors generated from other tests in the testing sequence. For 
example, you may also clear errors generated from other tests in the testing 
sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected 
time slot and never crosses over to time slots reserved for other connections. If 
the NPE is not working correctly, one-way and noisy connections may be 
observed. This test is usually part of a port’s long test sequence and takes about 
20 to 30 seconds to complete.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
 D = Destructive; ND = Nondestructive
Digital Looparound Test (#171)
X
X
ND
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Audit Update Test (#36)
X
X
ND
Table 9-191.
TEST #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run test are not available. The port may be in 
use on a valid call. Use status data-module to determine when the port is 
available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1001
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page