Lucent Technologies Release 7 Benutzerhandbuch

Seite von 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-934
ISDN-PLK (ISDN-PRI Signaling Link Port) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
The command to test the ISDN-LNK MO is test port UUCSSpp where pp is 24 for 
24-channel interfaces and 16 for 32-channel interfaces.
Signaling Link Board Check (#643)
This test checks the health of the TN464C/D UDS1 Interface transporting the 
ISDN-PRI Signaling Link Port
Signaling Port LAN Loopback Test (#939)
This test is destructive.
This test verifies the connectivity of an ISDN-PRI signaling port (D-channel) 
across the LAN bus, also known as the packet bus. It will execute only if the port 
is out-of-service. Failure of this test indicates a fault associated with the port 
hardware on the circuit pack.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Signaling Port LAN Loopback Test (#939)
X
D
Signaling Link Board Check (#643)
X
X
ND
Table 9-359.
TEST #643 Signaling Link Board Check 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this D-channel 
port is detached from the circuit pack. This is normal when the rollabout video 
feature is enabled. To complete a test on this port:
1. Re-attach the disconnected PRI terminal adapter
2. Disable the rollabout video feature on this board by entering change ds1 
UUCSS and set the ‘‘Alarm when PRI Endpoint Detached?’’ field to ‘‘y.’’
8
FAIL
The UDS1 TN464C/D circuit pack is not in-service.
1. Check the Hardware Error Log for entries logged against UDS1-BD, and 
consult “UDS1-BD” for repair procedures.
PASS
The UDS1 Interface circuit pack transporting the ISDN-PRI Signaling Link Port 
is in-service.