DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-79
Packet Bus Fault Isolation and Repair 
5
 is the starting point for the 
troubleshooting process. It is used to determine if a failure of service is 
caused by the packet bus itself or by another maintenance object on the 
packet bus.
 presents the procedures required to 
correct either a problem with the packet bus itself or one that is caused by 
a circuit pack connected to the Packet Bus.
Remote Maintenance versus On-Site 
Maintenance
Most packet bus fault isolation and repair procedures require a technician to be 
on-site. This is because a packet bus failures are caused by a hardware failure of 
either the packet bus itself or a circuit pack that is connected to it. Initial 
diagnoses can be made via use of the Packet Bus Fault Isolation Flowchart, but 
the Maintenance/Test Standalone Mode Procedure and the Packet Bus Fault 
Correction Procedure require that a technician be on-site. These procedures are 
presented with this requirement in mind.
The flowchart refers to the repair procedures in 
Chapter 9, ‘‘Maintenance Object 
Repair Procedures’’
 for various maintenance objects. When a decision point is 
reached, a remotely located technician can refer to the appropriate section and 
attempt to resolve any fault conditions. Some procedures require on-site repair 
action. Keep in mind that failure of a maintenance object appearing early in the 
flowchart can cause alarms with maintenance objects that appear later in the 
flowchart. Multiple dispatches can be prevented by remotely checking 
subsequent stages on the flowchart and preparing the on-site technician for 
replacement of several components if necessary.
The Maintenance/Test packet bus port described below provides status 
information that is accessed with the status port-network P command and the 
PKT-BUS test sequence. The Maintenance/Test circuit pack may or may not be 
present at a customer site, depending on the configuration of the switch. If a 
Maintenance/Test circuit pack is not present, one must be taken to the site for 
diagnosing packet bus problems.
In a system with duplicated SPEs, an SPE interchange may resolve the packet 
bus problem. This operation can be executed remotely, and is discussed in 
Packet Bus Fault Correction Procedures below.