Maintenance Architecture 
1-6
How to use the Maintenance book 
1
Alarms are further classified as:
On-board problems originate in the circuitry on the alarmed circuit pack.
Off-board problems originate in a process or component that is external to 
the circuit pack.
To clear system alarms using the appropriate maintenance book:
1. Type display alarms and press 
Enter
2. A query screen displays next (
Screen 1-1
), asking you if you want to see 
all alarms or if you want to restrict the list to certain kinds of errors. 
Screen 1-1.
Alarm Report query screen
Table 3.
Alarm levels, reporting conditions and action to take
Alarm 
level
Description
Reported
to
INADS?
Reported
to
console?
What action to take?
MAJOR
Critical service 
degradation
Y
Yes, after 4 
attempts to 
call INADS
Immediate attention
MINOR
Some service 
degradation but does not 
render the system 
inoperable.
Y
Same as 
above
Check to see what service 
is affected
WARNING
Failure that causes no 
significant service 
degradation
N
1
1.
Some system-downgraded Warning alarms are reported to INADS.
N
Monitor the situation. May 
be service or equipment 
interruption or failure 
outside the switch.
                                  ALARM REPORT
      The following options control which alarms will be displayed.
        ALARM TYPES
                   Active? y    Resolved? n
                    Major? y       Minor? y      Warning? y
        REPORT PERIOD
                 Interval: m      From:   /  /  :      To:   /  /  :  
        EQUIPMENT TYPE ( Choose only one, if any, of the following )
                             Cabinet:   
                        Port Network:   
                        Board Number:      
                                Port:        
                            Category: