DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-93
display errors 
8
The following display shows a typical result when disp errors is entered with the 
default input settings.
Seq Cnt
Sequence Count. These numbers give the order in which the errors 
were logged. Each sequence covers a period of one second. Sequence 
numbers are assigned to the first and last occurrences of a given error 
within the one second period given in the time stamp. There may be 
gaps in the sequence numbers within a given second because the last 
occurrence of an error may replace an existing entry and because 
sequence numbers are also assigned to software events not shown in 
the hardware error log. This information is displayed only if the 
high-resolution option is specified on the command line.
Last Occur
The month, day, hour, and minute (and second if the high-resolution 
command line option is used) of the most recent error. If the system is 
unable to retrieve the time of day when the error occurred, a “dummy” 
date will be stamped in the log so as to distinguish it from reliable data. 
It appears as “00/00/01:07”
Err Cnt
The total number of times that the error type has occurred. The 
maximum entry displayed is 999.
Err Rt
Average hourly rate at which the error has occurred from the first 
occurrence to the present. The maximum entry displayed is 999.
Rt/Hr
An approximation of the rate at which this error occurred in the last hour. 
The maximum entry displayed is 999.
Al St
Alarm Status - A character indicating the status of this MO in the error 
and alarm logs. The allowed values are:
 
Active alarm entry
 
Resolved alarm entry
 
Resolved alarm entry as a result of the long “clear” option of 
the test command.
 
Resolved alarm entry as a result of a software requested 
(non-demand) system restart.
 
Resolved alarm entry as a result of a technician requested 
system restart.
 
Not alarmed.
Ac
A flag (yes or no) indicating whether or not the maintenance object is 
still under active consideration by the maintenance subsystem.