Maintenance Commands 
8-276
status health 
8
SPE Power
Current source of power to the PPN
commercialThe SPE is currently powered by the normal external 
power source.
backupThe SPE is currently powered by the backup batteries. This is 
usually due to a failure of the external power source.
Time Source
The current source of timing signals used for system synchronization
For systems with a Stratum 3 clock:
externalNormal operating condition
internalAnother source besides the Stratum 3 clock, such as a 
Tone-Clock circuit pack, is providing the master timing signal.
For systems with Stratum 4 timing:
primaryThe primary administered timing source
secondaryThe secondary administered timing source
localAnother source besides the administered ones, such as a 
Tone-Clock circuit pack, is providing the master timing signal.
# Logins
Number of current users
Cab
Cabinet number
Cabinet numbers can be related to port network numbers with the list 
cabinet
 command.
Emerg Trans
The current setting of the switches on the SYSAM and EPN Maintenance 
circuit packs that control Emergency Transfer
Chapter 9
. For a PPN cabinet with duplicated SPEs, 
settings for both SYSAM circuit packs are displayed; 
auto 
is then 
abbreviated to 
a
, and 
off
 to 
of
. If the Emergency Transfer switch 
setting on a standby SYSAM is changed while handshake is down, this 
field will display the prior value until handshake is restored.
auto -
 Emergency Transfer is under system control and is not 
currently activated (normal operating state).
auto +
 Emergency Transfer is under system control and is in effect.
on
 Emergency Transfer has been manually activated. This setting 
should only be in effect during an emergency.
off
Emergency Transfer is manually prevented from occurring. This 
setting should only be in effect when a technician is on site.
n.a.
The setting of the switch in this EPN is not available to the 
switch. The Expansion Archangel Link may be down.
Mj, Mn, Wn
Number of Major, Minor or Warning alarms associated with the cabinet
An asterisk indicates that the number exceeds 99.