Lucent Technologies Release 7 Benutzerhandbuch

Seite von 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-297
status port-network 
8
Dedicated 
Tones
This field shows whether the TDM bus has the system tones on it 
(“y”/”n”). Only one TDM bus of a TDM bus pair can have system tones on 
it at a given time. If the system does not contain an EPN, blanks appear 
in this field. 
TONE/CLOCK
The location of the tone-clock circuit packs in the specified Port Network. 
The location is represented using the cabinet and carrier where the 
tone-clock resides (e.g. 1a, 1b, 2a, 2b, etc.).
Service 
State
This field represents the operational state of the tone-clock circuit pack. 
A service state of "in" means the tone-clock has been installed and is in 
normal operation. A service state of "out" means that the tone-clock is out 
of service and has failed certain maintenance tests. 
System 
Clock
This field shows which tone-clock circuit pack supplies the system clock 
for that port network by displaying the mode of the tone-clock. An 
“active” mode means that the tone-clock supplies the system clock. Only 
one tone-clock in each Port Network can have a mode of “active” at any 
given time. A “standby” mode means the tone-clock is part of a 
duplicated clock system and is ready to supply the system clock, but is 
not currently “active.” A “down” mode means the tone-clock is not 
operational.
System 
Tones
This field shows which tone-clock circuit pack supplies the system tones 
for that port network by displaying the mode of the tone-clock. An 
“active” mode means that the tone-clock supplies the system tones. Only 
one tone-clock in each Port Network can have a mode of “active” at any 
given time. A “standby” mode means the tone-clock is part of a 
duplicated clock system and is ready to supply system tones, but is not 
currently “active.” A “down” mode means the tone-clock is not 
operational.
PKT
This field contains the Packet Bus identifier, which is the same as the Port 
Network number.
Service 
State
This field represents the operational state of the packet bus. A service 
state of “in” means the packet bus has been installed and is in normal 
operation. A service state of “out” means that the packet bus is out of 
service and has failed certain maintenance tests, or the maintenance 
object has been demand busied out. A service state of “reconfig” means 
that the Maintenance/Test circuit pack has swapped one or more signal 
leads because of lead faults detected during testing (Duplex System 
Only). A service state of “open lds” means the Maintenance/Test circuit 
pack query was run and open bus leads were found. A service state of 
Blanks in this field means the system does not have the Packet Bus 
feature optioned.
Major 
Alarms
Whether major alarms are logged against the packet bus that is being 
displayed ("y" or "n").
Minor 
Alarms
Whether minor alarms are logged against the packet bus that is being 
displayed ("y" or "n").