Lucent Technologies Release 7 Benutzerhandbuch

Seite von 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-350
test led 
8
test led
test led [all | cabinet UU | port-network PN# | switch-node SN# | a-pnc | 
b-pnc] [repeat #]
This command verifies that a specified cabinet, port network, PNC or switch 
node is recognized by the system. It is also useful for identifying a port network, 
cabinet, or PNC (A or B).
When test led is entered, the red, green and yellow circuit pack LEDs are turned 
on until all administered carriers in the specified group have been lit for 2 
seconds. They are then turned off in the same order in which they came on. The 
cycle can be repeated a number of times with the repeat option. Once all of the 
repeat cycles are completed, all affected LEDs are restored to reflect their 
current status.
test link
test link link [short | long] [repeat | clear] [schedule]
This command verifies that the specified link is administered and performs a 
series of tests on the link.
Parameters
Output
Port
Each link is identified by a number (1-16) assigned on the 
Communication-Interface Links form. Display communication-interface 
links
 shows the location and identification of each link.
Port
The location of the port on a Packet Gateway circuit pack associated with the 
link being tested.