Linear LTC3562 Benutzerhandbuch

Seite von 7
DC1123 QUICK START GUIDE 
 
 
output  voltages  adjusted  through  I
2
C  control  from 
600mv to 3.775V in 25mv increments. 
 
Q U ICK  STA RT PROCEDU RE 
U sing short tw isted pair leads for any pow er connec-
tions and w ith all loads and pow er supplies off, refer 
to  Figure  1  for  the  proper  measurement  and  equip-
ment setup.  
 
NOTE.
 W hen measuring the input or output voltage ripple, care must be 
taken to avoid a long ground lead on the oscilloscope probe. M easure the 
input or output voltage ripple by touching the probe tip directly across the 
VCC or VO UT and G ND terminals. See Figure 2 for proper scope probe 
technique. 
1.
 Place jumpers and load settings in the follow ing posi-
tions: 
JP1 (RUN600A) = O N 
        
JP2 (RUN400A) = O N 
        
Load 1 = Consant Current 50mA 
        
Load 2 = Constant Current 50mA 
        
Load 3 = Constant Current 50mA 
        
Load 4 = Constant Current 50mA 
2.
 Connect Pow er Supply PS1 to VIN terminals and ad-
just to 4.5 Volts to the demo board, as show n in Fig-
ure 1. 
3.
 Verify that OUT600A (1.8V) and OUT400A (1.5V) are 
operational w ith proper output voltages. 
4.
 Once the proper output voltages are established, ad-
just the loads w ithin the operating range and observe 
the output voltage regulation, ripple voltage, and effi-
ciency. 
5.
 Open  the  Quickstart  Softw are  as  discribed  in  the 
DC590 Q uick Start G uide 
6.
 Set Jumpers JP1 (RUN400A) and JP2 (RUN600A) to 
O ff Position. Connect Ribbon cable from DC590 demo 
circuit  to  J2.  The  LTC  3562  demonstation  softw are 
should  pop-up  automatically  w hen  the  cable  is  in-
stalled. 
7.
 Using the LTC3562 softw are GUI. See Figure 3. Set all 
modes  to  Burst  mode,  VO U T  600A  to  1.82V,  VO U T 
600B to 3.3V, VO U T 400A to 1.51V and VO U T 400B to 
1.2V.  Set all loads  to  50mA.  Check Auto  U pdate  but-
tons. Click on Enable All button. 
8.
  Once the proper output voltages are established, ad-
just the loads w ithin the operating range and observe 
the output voltage regulation, ripple voltage, and effi-
ciency. 
9.
 Using  the  LTC3562  softw are  GUI.  Set  all  modes  to 
Pulse Skip mode, VO U T 600A to 1.82V, VO U T 600B to 
3.3V,  VO U T  400A  to  1.51V  and  VO U T  400B  to  1.2V. 
Set all loads to 50mA.  
10.
 Once the proper output voltages are established, ad-
just the loads w ithin the operating range and observe 
the output voltage regulation, ripple voltage, and effi-
ciency. 
11.
 Using  the  LTC3562  softw are  GUI.  Set  all  modes  to 
Forced Burst mode, VO U T 600A to 1.82V, VO U T 600B 
to 3.3V, VO U T 400A to 1.51V and VO U T 400B to 1.2V. 
Set all loads to 50mA.  
12.
 Once the proper output voltages are established, ad-
just the loads w ithin the operating range and observe 
the output voltage regulation, ripple voltage, and effi-
ciency 
13.
 Using  the  LTC3562  softw are  GUI.  Set  all  modes  to 
LDO mode, VO U T 600A to 1.82V, VO U T 600B to 3.3V, 
VO U T 400A to 1.51V and VO U T 400B to 1.2V. Set all 
loads to 50mA.  
14.
 Once the proper output voltages are established, ad-
just the loads w ithin the operating range and observe 
the output voltage regulation, ripple voltage, and effi-
ciency 
15.
 Using  the  LTC3562  softw are  GUI.  Set  all  modes  to 
Burst  mode,  VO U T  600A  to  1.82V,  VO U T  600B  to 
3.3V,  VO U T  400A  to  1.51V  and  VO U T  400B  to  1.2V. 
Set all loads to 50mA.  
16.
 M onitor  POR600A  pin  w hile  increasing  Load1  until 
the  signal  on  PO R 600A  goes  low .  The  voltage  on 
P600A w ill be less than 92%  of voltage setting.