8.0 GENERAL INFORMATION
TECHNICAL INFORMATION-SINGLE STAGE
N37K
N45K
N50H
N60H
General 
Sound pressure level dB(A) * 
75 
75 
75 
75 
Maximum ambient temperature ° C (° F) 
46 (115) 
46 (115) 
46 (115) 
46 (115) 
Minimum ambient temperature ° C (° F) 
1.7 (35) 
1.7 (35) 
1.7 (35) 
1.7 (35) 
Weight Kg (lbs) 
1048 (2310) 
1048 (2310) 
1048 (2310) 
1048 (2310) 
Maximum pressure barg (psig) 
10 (145) 
10 (145) 
10 (145) 
10 (145) 
Minimum pressure barg (psig) 
4.5 (65) 
4.5 (65) 
4.5 (65) 
4.5 (65) 
Coolant capacity litres (US gal) 
18 (4.8) 
18 (4.8) 
18 (4.8) 
18 (4.8) 
HAT switch setting ° C (° F) 
120 (248) 
120 (248) 
120 (248) 
120 (248) 
Performance **
Flow at 7.5 Barg (m³/min) 
6.43 
7.39 
− 
− 
Flow at 8.5 Barg (m³/min) 
6.12 
7.02 
− 
− 
Flow at 10 Barg (m³/min) 
5.83 
6.46 
− 
− 
Flow at 100 psig (cfm) 
− 
− 
235 
262 
Flow at 125 psig (cfm) 
− 
− 
216 
248 
Flow at 140 psig (cfm) 
− 
− 
209 
233 
Air Cooling System  
Cooling air flow m3/min (cfm) 
184 (6500) 
184 (6500) 
184 (6500) 
184 (6500) 
Maximum ΔP in air ducts Pa (inch WG) 
124 (0.5) 
124 (0.5) 
124 (0.5) 
124 (0.5) 
Compressed air outlet ΔT ° C (° F) 
8 (15) 
8 (15) 
8 (15) 
8 (15) 
Water Cooling System  
Cooling (clean) water flow l/min (US 
gallon/min) @ 10 ° C (50 ° F) / 32 ° C  
(90 ° F) 
23/38  (6/10) 
27/49  (7/13) 
23/38  (6 /10) 
27 /49  (7 /13) 
Maximum ΔP in air ducts Pa (inch WG) 
62 (0.25) 
62 (0.25) 
62 (0.25) 
62 (0.25) 
Compressed air outlet ΔT ° C (° F) 
14 (25) 
14 (25) 
14 (25) 
14 (25) 
Main Power Circuit A/C (W/C) *** 
Package full load current at 220V (A) **
140 (131) 
168 (159) 
140 (131) 
168 (159)
Package full load current at 400V (A) **
75 (70 ) 
90 (85) 
− 
Package full load current at 460V (A) **
− 
− 
68 (63) 
81 (77)
Package full load current at 575V (A) **
− 
− 
56 (52) 
67 (63)
Max fuse size @ 220V (A) 
250 
250 
250 
250
Max fuse size @ 400V (A) 
125 
125 
125 
125
Max fuse size @ 460V (A) 
125 
125 
125 
125
Max fuse size @ 575V (A) 
100 
100 
100 
100
Fuse type 
Fast acting class J, T or semiconductor type, current limiting interrupt 
rating 200, 000 Amps RMS SYM.
Heater Circuit 
110V Single Phase Rating (A) 
4
230V Single Phase Rating (A) 
4
Fuse type 
General purpose  
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable  
      size should be  calculated on basis of mean package full load current X1.25 (i.e. 25% margin)