11.0 FAULT FINDING
11.1 GENERAL FAULTS
 WARNING
When attempting to identify and remedy any fault or failure, ensure it is only attempted by qualified person-
nel and that the safety and maintenance sections of this manual have been read and are fully understood and 
followed. Major overhauls should only be carried out by a qualified Ingersoll Rand representative. Failures 
caused by fitting parts not recommended by Ingersoll Rand or non−authorized Ingersoll Rand personnel may 
not be covered by the terms of any warranty agreement
SYMPTOM 
FAULT 
REMEDY 
Compressor will not 
start 
No power supply to package 
Check supply is switched on. If so, contact a 
qualified electrician.
Intellisys controller failure  
 Check supply to unit. Replace unit.
Starter failure
Isolate supply, lock off and tag. Replace 
failed
component or contact your local  
Ingersoll Rand representative 
Compressor stops and 
will not restart 
 
Drive controller has tripped 
See section 11.2 & 11.3 
Intellisys controller has tripped the 
compressor
See section 11.2 & 11.3
Maximum number of starts per hour 
exceeded
Compressor is stopped 
and will not restart 
Intellisys controller has tripped the 
compressor and has not been reset
See section 11.2 & 11.3
Emergency stop has been pressed and 
not released
Identify reason why, repair fault, disengage 
button and reset Intellisys controller
Emergency stop has been pressed and 
released but Intellisys controller has not 
been reset
Repair fault and reset Intellisys controller