HU500000, HU502000
www.chpower.com
Installation
lOCatIOn
It is extremely important to install the 
compressor in a clean, dry, and well 
ventilated area. The compressor must 
be placed on a firm, level surface where 
the surrounding air temperature will 
not be more than 100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.
 
Do not locate the  
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
eleCtrICal InStallatIOn 
 
All wiring   
  and 
electrical connections should 
be performed by a qualified 
electrician. Installation must 
be in accordance with local codes and 
national electrical codes.
WIrInG
1.  Local electrical wiring codes 
differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum.
2.  Use a slow blow fuse or a circuit 
breaker.
3.  This product is for use on a 
nominal 120 volt circuit and has 
a grounding plug that looks like 
the plug illustrated in Figure 6. 
Make sure the product is connected 
to an outlet having the same 
configuration as the plug. This 
product must be grounded. In the 
event of an electrical short circuit, 
grounding reduces risk of electrical 
shock by providing an escape wire 
for electric current. This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug. Plug must be 
plugged into an outlet that is 
properly installed and grounded in 
accordance with all local codes and 
ordinances.
 
Overheating, short  
  circuiting and fire 
damage will result from inadequate 
wiring.
TEST
RESET
Figure 6 - Grounding Method
Grounded Outlet
Grounding Pin
Operation
beFOre FIrSt Start-Up
break-In prOCeDUre
(Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.)
1.  Open drain valve located on bottom 
of tank.
2.  Turn On / OFF switch to OFF 
position.
3.  Plug in power cord.
4.  Turn On / OFF switch to On position 
and run compressor for 30 minutes.
5.  Turn On / OFF switch to OFF 
position.
6.  Unplug power cord.
7.  Close drain valve.
The compressor is now ready for use.
OperatInG prOCeDUre
1.  Turn switch to OFF position and plug 
in power cord.
2.  Turn regulator knob 
counterclockwise to close air flow.
3.  Turn switch to aUtO position.
4.  Compressor will build to maximum 
pressure and shut off.
5.  With hose attached to outlet of 
compressor, attach tire chuck or 
other tool to open end of hose.
6.  Adjust regulator to proper pressure 
for tool or tire. Operate tool per 
instructions. 
As air is depleted from the tank by 
use of a tire chuck, tool, etc., the 
compressor will restart automatically 
at its preset “cut-in” pressure. When 
a tool is being used continuously, 
the compressor will cycle on and off 
automatically.
7.  Turn switch to OFF position, unplug 
power cord and drain tank of air 
when finished using compressor.
Minimum Gauge of Extension Cord
25 ft.
50 ft.
100 ft.
14
12
10
Use of an extension cord may cause excess 
heat to motor. This could lead to tripped 
breaker (at electrical panel) or tripped 
thermal overload (on compressor motor). 
If this occurs, eliminate extension cord and 
plug compressor directly into electrical 
outlet. Avoid using extension cords; use 
longer air hose(s) instead.