Samsung 100737108-A Benutzerhandbuch

Seite von 83
Spinpoint M8-DVR OEM Product Manual REV 1.0 
58 
 
 
 
 
   
The  contents  of  the  Command  Block  registers,  following  the  transfer  of  a  data  block,  which  had  a  sector  in 
error, are undefined. The host should retry the transfer as individual requests to obtain valid error information. 
 
Subsequent  blocks  are  transferred  only if  the  error  was  a  correctable  data  error.  All  other  errors  cause  the 
command  to  stop  after  transfer  of  the  block,  which  contained  the  error.  Interrupts  are  generated  when  DRQ  is 
set at the beginning of each block. 
 
 
 
8.2.18 Read Native Max Address (F8h, 27h: extended) 
 
 
 
This  command  returns  the  native  maximum  address.  The  native  maximum  address  is the  highest  address 
accepted  by  the  device  in  the  factory  default  condition.  The  native  maximum  address  is  the  maximum 
address that is valid when using the SET MAX ADDRESS command. 
 
8.2.19 Read Sector(s) (20h, 24h: extended) 
 
 
 
This  command  reads  from  1  to  256  sectors  as  specified  in  the  Sector  Count  register.  A  sector  counts  of  0 
requests  all  256  sectors  if  the  command  is  Read  Sectors  (not  Read  Sector  Extended).  The  transfer  begins  at 
the sector specified in the Sector Number register. 
 
If  the  drive  is  not  already  on  the  desired  track,  an  implied  seek  is  performed.  Once  at  the  desired  track,  the 
drive searches for the appropriate ID field. 
 
If  the  ID  is  read  correctly,  the  data  address  mark  shall  be  recognized  within  a  specified  number  of  bytes,  or 
the  Address  Mark  Not  Found  error  is  posted.  DRQ  is  always  set  prior  to  data  transfer,  regardless  of  the 
presence or absence of an error condition. 
 
At  command  completion,  the  Command  Block  registers  contain  the  address  of the  last  sector  read.  If an  error 
occurs,  the  read  terminates  at  the  sector  where  the  error  occurred.  The  Command  Block  registers  contain  the 
address of the sector where the error occurred. 
 
 
8.2.20   
Read Verify Sector(s) 
(40h, 41h: extended) 
 
 
 
This  command  is  obsolete  in  the  ATA7  specification.  The  supporting  of  this  command  is  for  backward 
compatibility  purpose.  The  use  of  this  command  is  beyond  the  ATA  standard  and  not  recommended  by  the 
manufacturer. 
 
This  command  is  identical  to  the  Read  Sectors  command,  except  that  DRQ  is  never  set,  and  no  data  is 
transferred to the host. 
 
When  the  requested  sectors  have  been  verified,  the  drive  clears  BSY  and  generates  an  interrupt.  Upon 
command  completion,  the  Command  Block  registers  contain  the  address  of  the  last  sector  verified.  If an  error 
occurs, the Verify terminates at the sector where the error occurred. 
 
The  Command  Block  registers  contain  the  address  of  where  the  error  occurred.  The  Sector  Count  register 
contains the number of sectors not yet verified.