6.Command Specification 
RECEIVE DIAGNOSTIC RESULTS
 
6-78 
 
SONY AIT-3Ex drive SDX-800V series Ver.1.1 
All error messages are of the same format. All fields within the error message may not be known or applicable and 
are cleared to ZERO. A diagnostic result of all ZEROs is returned if the diagnostic completed successfully without 
error. 
Table 6-79: RECEIVE DIAGNOSTICS results data 
Bit 
Byte 
7 6 5 4 3 2 1 0 
Reset 
Error 
Time 
Re-Sync 
(0) 
Reserved Error 
Set 
Error Code 
Result A 
Result B 
Test Number 
Reset error: This bit is set when an error occurs during power-on self-test. 
Time Re-Sync: This bit indicates that the time stamp saved with the error log has no relation to that of the previous 
entry. It is only set by the logging routine within the data buffer as an error is logged. This field is not supported.  
Error set: Various set of error codes exist. The definition of the error is dependent upon when set is taken from as 
follows: 
0 - Runtime errors 
1 - Drive mechanism diagnostic errors 
2 - Drive electronics diagnostic errors 
Error code: Error codes for each error set are defined in the Diagnostics clause. 
Result A and B: The content of these bytes depends on the test being run. See the Diagnostics clause. 
Test number: This is the test number to which the message applies (if a test fails within a sequence, the individual 
test number will be returned).