Hitachi HDS721025CLA382 Benutzerhandbuch

Seite von 258
Hitachi hard disk drive specifications   
94 
9.18.3.2 
Error Recovery Control command (action code : 0003h) 
Inputs: (Key Sector) 
Word 
Name 
Value 
Description 
Action Code 
0003h 
Set the read and write error recovery time 
Function Code 
0001h 
Set New Value 
0002h 
Return Current Value 
Selection Code 
0001h 
Read Timer 
0002h 
Write Timer 
Value 
Word 
If the function code is 0001h, then this field contains the 
recovery time limit in 100ms units. The minimum SCT 
timeout value is 65 (=6.5 second). When the specified time 
limit is shorter than 6.5 second,the issued command is 
aborted. 
255:4 
reserved 
0000h 
 
Table 57    Error Recovery Control command (Inputs) 
Outputs: (TF Data) 
Command Block Input Registers (Success) 
Error 
00h 
Sector Count 
If Function Code was 0002h, then this is the LSB of the requested recovery limit. 
Otherwise, this field is reserved. 
Sector Number 
If Function Code was 0002h, then this is the MSB of the requested recovery limit. 
Otherwise, this field is reserved. 
Cylinder Low 
reserved 
Cylinder High 
reserved 
Device/Head 
reserved 
Status 
50h 
Table 58    Error Recovery Control command (Onputs) 
The Error Recovery Control command can be used to set time limits for read and write error recovery. For 
non-queued commands, these timers apply to command completion at the host interface. For queued 
commands where in order data delivery is enabled, these timers begin counting when the device begins to 
execute the command, not when the command is sent to the device. These timers do not apply to streaming 
commands, or to queued commands when out-of-order data delivery is enabled. 
 
These command timers are volatile. The default value is 0 (i.e. disable command time-out).