Can Not See Devices or Drives
Possible reasons why you can not see devices or drives:
Some devices are not powered on. Some adapter have a separate green 3.3V power indicator 
LED (see page 19).
The LEDs indicate that the link is down. On an adapter, a link-down is indicated when the 
green LED flashes and the yellow LED is off (see Table 1 on page 20). On a switch, the LED 
states vary depending on the switch vendor. See the switch vendor’s documentation.
The cable is not working. Use a cable from a known working connection to test. Isolate the 
problem to the adapter, cable or connected device. 
The driver is improperly installed or loaded. Verify that a compatible driver is completely 
installed and loaded. Some devices may require a specific device driver installed on the host. 
Automap is turned off. The first time the machine boots with automap off, the devices are not 
mapped to the OS. See the HBAnyware Utility User Manual for more information where 
applicable.
On the FC Port driver, automap is off by default. Enable it using the HBAnyware utility.
On the Storport Miniport and SCSIport Miniport drivers, automap is on by default. Change it 
with the HBAnyware utility.
On the driver for Solaris, automap is on by default. Change it using the HBAnyware utility.
On the driver for Linux, lpfc_automap is on by default. Change it using the HBAnyware 
utility.
On the driver for HP-UX, automap is on by default and automatically assigns SCSI IDs by 
World Wide Port Name (WWPN). Three parameters (scan-down, fc-bind and automap) 
control how the Emulex driver maps FC devices. Change parameters at the command line. 
See the driver user manual for more information.
The targets are not discovered. Use the HBAnyware utility to determine discovered targets.
To find the number of targets, click on Discovered Elements in the discovery-tree.
To view information specific to a target, sort by host name and click on the Target 
Attributes 
tab.
The switch is configured incorrectly. The adapter must be in the proper zone to see the target 
device. 
The array is configured incorrectly. Check settings in the RAID system security settings. 
Verify that the array knows the adapter world wide node name (WWNN).
Out-of-Date Driver Version
These symptoms indicate you may need to update your driver. For more information, see page 1.
Target devices appear incorrectly in device manager.
The Emulex driver operated correctly before cluster services were installed, but now that 
the server has rebooted, the cluster will not start or there are connection time-outs.
 Verify 
with the software vendor that you have the latest versions of software and that you are running 
Emulex drivers and firmware that are qualified for that software.
Problem with third-party management software. Verify with the software vendor that you 
have the latest versions of software and that you are running Emulex drivers and firmware 
qualified for that software.
An operating system error (blue screen) occurs.
Tape operation problems.