Carrier Access 1750 Benutzerhandbuch

Seite von 420
Broadmore 1750 - Release 4.6
8-13
 
Maintenance and Troubleshooting
24-Hour Statistics
24-Hour Statistics
Statistics for the most recent 24-hour period are maintained for DS3 modules. Statistics 
for each port are maintained in a file that may be transferred via FTP to a PC and 
viewed, using a spreadsheet program such as Microsoft Excel. The files are in the 
STATS directory, and named according to the following sequence:
STATS\DS3C1.STA
STATS\DS3C2.STA
STATS\DS3C3.STA
STATS\DS3F1.STA   (and so on)
The C1 represents slot C port 1, C2 represents slot C port 2, and F1 represents 
slot F port 1.
Statistics are maintained according to the following:
A file is created when a PVC or SVC is activated on a port.
Statistics for a port are not recorded after the associated PVC is released.
Statistics are PVC and SVC dependent. When a PVC or SVC is established on a 
port previously in use, the old statistics are moved to a “discard directory” and 
new statistics are maintained.
The discard directory only retains statistics for the most recently released PVC or 
SVC on any given port.
Use a standard spreadsheet program (such as Excel) to open a statistics file. Adjust the 
column widths as necessary to match the printer/paper size in use so that the data may 
be displayed on a single sheet of paper.