8-36
Broadmore 1750 - Release 4.6
Maintenance and Troubleshooting
CPU IOM Replacement
9. Return the defective CPU card for repair. Contact Customer Service for an 
RMA number and detailed procedures.
CPU IOM Replacement
There are no field-repairable items on the CPU IOM. This module does contain a 
unique part of the Ethernet address such that the Broadmore 1750 system must be 
alerted to the module change in order to restore service. Only replace the standby CPU 
or CPU IOM on a redundant system. This will ensure correct programming of the IP, 
CIP, LANE and ATM address information.
1. Ensure that you have a replacement CPU IOM with remote reboot jumpers set 
correctly.
2. Follow the CAMMI sequence on the next page to signal CPU IOM removal.
3. Loosen top and bottom retaining screws, use ejectors to unseat the module, and 
pull it straight out to remove.
4. Insert the replacement CPU IOM, ensuring alignment with the guides and 
midplane connector. Tighten both retaining screws (finger tight only).
5. Return the defective CPU IOM for repair. Contact  Customer Service for an 
RMA number and detailed procedures.
Fan Replacement
There are no field-repairable items on the fan tray assembly. The air filters are 
removable for routine cleaning. Removal and replacement of the fan assembly will not 
impact normal Broadmore 1750 operations. This replacement should be completed 
quickly to avoid possible overheating of Broadmore 1750 components. Follow the 
steps below to replace the fan assembly.
1. Ensure that you have a replacement fan tray assembly.
2. Loosen retaining screws on both sides of the fan assembly to be replaced.
3. Remove the defective fan assembly from below the chassis by pulling it 
straight out. 
4. Insert the replacement fan assembly, ensuring alignment in the side guides.