Standards Compliance for SNMP Traps
 B-2
8700-A2-GB20-00
April 2000
For a unit defined as an NTU running IP Conservative software, all traps have at
a minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula
for the SOI is:
   ((LTU Slot Number) * 1,000,000) 
+ ((LTU DSL Port Number) * 1,000) 
+ the NTU’s ifIndex.
warmStart
SNMP Trap
Description
Possible Cause
warmStart
The unit has reinitialized
itself.
The trap is sent after the unit
resets and stabilizes.
No variable bindings.
H
Reset command.
H
Power disruption.
authenticationFailure
SNMP Trap
Description
Possible Cause
authenticationFailure
Failed attempts to access
the unit.
Variable bindings:
H
devAuthentication
FailureIPAddress 
(Health & Status MIB)
Returns zero if the IP
address is unknown or the
failure came from the
terminal port.
Three unsuccessful attempts
were made to enter a correct
login/password combination.