Configuration Options
 A-11
8700-A2-GB20-00
April 2000
System Options
For System Options, refer to Table A-7. To access the System Options screen,
follow this menu selection sequence:
Main Menu
Configuration
Load Configuration From
System
Î
Î
ÎÎ
ÎÎ
main/config/system
  
Slot: 18
 Model: 87xx
  SYSTEM OPTIONS
DSL Mode:
LTU
Test Timeout:
Enable
Test Duration (min):
10
Telco Initiated Loopbacks:
Enable
(Models 8747, 8777)
Remote Telco Line Loopback:
Disabled
(Models 8747, 8777)
G.703 Line Termination
120 Ohm
(Model 8779)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
 Save
Table A-7.
System Options (1 of 2)
DSL Mode
Possible Settings: LTUNTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU – The unit is configured as a control unit (Line Termination Unit).
NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
NOTE:
Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
 in Chapter 8, Testing.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a test to run before terminating.