Paradyne 8777 Benutzerhandbuch
Configuration Options
A-11
8700-A2-GB20-00
April 2000
System Options
For System Options, refer to Table A-7. To access the System Options screen,
follow this menu selection sequence:
follow this menu selection sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
System
Î
Î
ÎÎ
ÎÎ
main/config/system
Slot: 18
Model: 87xx
SYSTEM OPTIONS
DSL Mode:
LTU
Test Timeout:
Enable
Test Duration (min):
10
Telco Initiated Loopbacks:
Enable
(Models 8747, 8777)
Remote Telco Line Loopback:
Disabled
(Models 8747, 8777)
G.703 Line Termination
120 Ohm
(Model 8779)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu
MainMenu
Exit
Save
Table A-7.
System Options (1 of 2)
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU – The unit is configured as a control unit (Line Termination Unit).
NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
request its IP address from the LTU during establishment of the PPP link.
NOTE:
Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
remotely managed, so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
Disable – Tests run until manually terminated from the Network Tests screen or
remotely (network initiated tests). Refer to
remotely (network initiated tests). Refer to
in Chapter 8, Testing.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a test to run before terminating.